The STLink API that supports dap-direct is available from STLink firmware v2j24, published in early 2015. We can reasonably expect that any old STLink still in use today has got at least one firmware update during the last 10 years. Most of the board files in upstream OpenOCD still use the STLink in HLA mode. This limits the test coverage of the dap-direct code, which was introduced in OpenOCD v0.11.0. - Rename interface/stlink.cfg as interface/stlink-hla.cfg to still provide support for HLA, adding a deprecated message. - Rename interface/stlink-dap.cfg as interface/stlink.cfg to make dap-direct the default trasport. - Add a redirect file interface/stlink-dap.cfg for users that have out-of-tree custom board files. - Update all the board files to the new setup. - Remove STLink HLA mentions from the documentation, while adding a reference to interface/stlink-hla.cfg Checkpatch-ignore: LONG_LINE Change-Id: I99366bb03cd3b83f8f408514e657f30e59813063 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: https://review.openocd.org/c/openocd/+/8523 Tested-by: jenkins Reviewed-by: Andrzej Sierżęga <asier70@gmail.com>
22 lines
874 B
INI
22 lines
874 B
INI
# SPDX-License-Identifier: GPL-2.0-or-later
|
|
|
|
#
|
|
# STMicroelectronics ST-LINK/V1, ST-LINK/V2, ST-LINK/V2-1, STLINK-V3 in-circuit
|
|
# debugger/programmer
|
|
#
|
|
|
|
echo "DEPRECATED: OpenOCD support for ST-Link HLA transport will be dropped soon!"
|
|
echo "Consider updating your ST-Link firmware to a version >= V2J24 (2015)"
|
|
|
|
adapter driver hla
|
|
hla layout stlink
|
|
hla device_desc "ST-LINK"
|
|
hla vid_pid 0x0483 0x3744 0x0483 0x3748 0x0483 0x374b 0x0483 0x374d 0x0483 0x374e 0x0483 0x374f 0x0483 0x3752 0x0483 0x3753 0x0483 0x3754 0x0483 0x3755 0x0483 0x3757
|
|
|
|
# Optionally specify the serial number of ST-LINK/V2 usb device. ST-LINK/V2
|
|
# devices seem to have serial numbers with unreadable characters. ST-LINK/V2
|
|
# firmware version >= V2.J21.S4 recommended to avoid issues with adapter serial
|
|
# number reset issues.
|
|
# eg.
|
|
# adapter serial "\xaa\xbc\x6e\x06\x50\x75\xff\x55\x17\x42\x19\x3f"
|